01.01
01.01
Are basic structures for all subsequent thermocouple modifications. Versions with terminal heads 005 and 006 are used as replaceable temperature elements in block-modular modifications of 01.07, 01.20, 01.21, 01.23, 01.24 sensors, and 01.06, 01.08, 01.16 sensors respectively.
These sensors are designed for temperature measurement in liquid and gaseous non-corrosive media, and also corrosive media that do not damage protective cover material.
Temperature sensor can be bent to locate hot junction in required measurement area. Bend radius is not less than five times of cable diameter.
01.01 modification is also executed as 000 version. It is necessary to take care during connection due to possible thermocouple wire damage. 01.02 or 02.01 modification s recommended as an operating sensor. List of possible terminal head designs is given in "Alternative designs & Ordering information" table below.
Movable fittings UNKJ 031 (see section 10) designed for 1.0 MPa rated pressure are used for sensor installation at site. For application area extension CTxx 01.02 thermocouples can be manufactured with welded (soldered) mounting elements in compliance with the Customer's drawings.
Hot junction |
one |
Ungrounded or |
|
two |
|||
Vibration resistance GOST R 52931 |
group V3 |
01.01 |
|
group F3 |
01.02 |
||
Nominal (rated) pressure |
0,1MPa without mounting elements |
up to 150MPa depending on mounting elements |
|
Seismic resistance MSK-64 |
grade 9 for unit installation up to 70 m above zero mark |
||
Climatic category GOST 15150 |
UHL2 |
Ambient temperature: -60..+120ºС |
|
Calibration |
MI 3090-2007 - for sensor fitting length 20 to 250 mm |
Instrument drift at calibration interval (CI)
Temperature sensor type |
Group of operating conditions |
Drift at CI, °С, not more |
CTK; CTN |
I; II |
± (1 or 0,004 · |t|) |
III |
± (1,5 or 0,006 · |t|) |
|
IV |
— |
|
CTL |
I |
± (1 or 0,004 · |t|) |
II |
± (1,5 or 0,006 · |t|) |
|
CTJ |
II |
± (1 or 0,004 · |t|) |
CTM |
II; III |
± (1 or 0,004 · |t|) |
Group of operating conditions |
Probability of |
Specified lifetime |
Mean |
Guarantee |
I |
0.95 for 40 000 hours |
5 years |
10 years |
5 years |
II |
0.95 for 16 000 hours |
2 years |
4 years |
2 years |
III |
0.95 for 8 000 hours |
1 year |
2 years |
1 year |
IV |
Not rated |
Not rated |
Not rated |
Not rated |
Measurement accuracy of sensors with 4-20 mА DC signal and/or digital signal via HART protocol are given taking into account accuracies of thermocouple itself, transmitter and transmitter's cold junction compensation.
Output signal |
Symbol |
Measurement accuracy |
Output |
Symbol |
Measurement accuracy |
4-20mА |
c0Т40 |
±0,4% ∙tn* or ±1,5°С |
4-20mА+HART |
c1N25 |
±0,25%∙ tn or ±0,9°С; |
c1Т50 |
±0,5%∙ tn or ±2,0°С |
c0N40 |
±0,4%∙ tn or ±1,2°С; |
||
c2Т80 |
±0,8%∙ tn or ±2,5°С; |
c1N50 |
±0,5%∙ tn or ±1,7°С; |
||
|
|
c2N80 |
±0,8%∙ tn or ±2,5°С; |
* - tn sensor adjustment range should be multiplied by specified value in %. Select higher value.
Response time τ 0,63:
Hot junction |
Sensor response time depending on diameter, c |
|||||||
d = 0,5 |
d = 1,0 |
d = 1,5; 2 |
d = 3,0 |
d = 4,0 |
d = 4,5; 4,6 |
d = 5,0 |
d = 6,0 |
|
Insulated from sheath |
0.05 |
0.15 |
0.4 |
1.0 |
1.5 |
2.0 |
3.0 |
4.0 |
Uninsulated from sheath |
0.03 |
0.05 |
0.15 |
0.5 |
1.0 |
1.0 |
1.5 |
2.0 |
Temperature range
CT type |
Application |
Group of |
Calibration |
Cable selection |
|
Sheath |
Sheath material |
||||
CTK |
– 40 .. + 600 |
I |
5 years |
3; 4; 4.5; 6 |
S321; S316; T310; Т446; T600 |
– 200 ..+ 600 |
II |
2 years |
1.5; 2; |
S321; S316; T310; T600 |
|
– 200 ..+ 800 |
3; 4; 4.5; 6 |
S321 |
|||
– 200..+ 900 |
3; 4; 4.5; 6 |
S316; T310; T600 |
|||
– 200 ..+ 800 |
III |
1 year |
1.5; 2; |
S321 |
|
– 200..+ 900 |
1.5; 2; |
S316; T310; T600 |
|||
– 200..+ 1000 |
3 |
T310; Т446; T600 |
|||
– 200..+ 1100 |
4.5; 6; |
T310; Т446; T600 |
|||
– 40 .. + 700 |
IV |
Not rated |
0.5 |
T310; T600 |
|
1 |
S321; T310; T600 |
||||
– 40..+ 1300 |
4.5; 6; |
T600 |
|||
CTN |
– 40 ..+ 800 |
I |
5 years |
3; 4.5; |
Т310; Т600; Т740 |
– 200 ..+ 600 |
II |
2 years |
1.5; 2; |
S321, S316 |
|
– 200 ..+ 800 |
1.5; 2; |
Т310; Т600; Т740 |
|||
– 200 ..+ 1000 |
3 |
T310; T600 |
|||
– 200 ..+ 1100 |
4.5 |
T310; T600 |
|||
3; 4.5; |
Т740 |
||||
– 200 ..+ 800 |
III |
1 year |
1.5; 2; |
S321, S316 |
|
– 200..+ 900 |
1.5 |
Т740, Т310; T600 |
|||
– 200 ..+ 1000 |
2 |
Т740, Т310; T600 |
|||
– 200 ..+ 1100 |
3 |
Т740, Т600, Т310 |
|||
– 200 ..+ 1200 |
4.5 |
Т740 |
|||
– 40 ..+ 800 |
IV |
Not rated |
1 |
Т600; Т740 |
|
– 40 ..+ 1300 |
4.5 |
Т740 |
|||
CTL |
– 40 ..+ 600 |
I |
5 years |
3; 4; 4.6; 5; 6 |
S10 |
– 100 . + 800 |
II |
2 years |
3; 4; 4.6; 5; 6 |
S10 |
|
– 100 ..+ 600 |
III |
1 year |
1.5 |
S10 |
|
– 40 ..+ 600 |
IV |
Not rated |
1 |
S10 |
|
CTJ |
– 40 ..+ 760 |
II |
2 years |
2; 3; 4.5 |
S321, S316 |
CTM |
– 40 ..+ 200 |
II |
2 years |
2; 3; 4.5 |
S10; S321 |
– 200 ..+ 370 |
III |
1 year |
CTK |
|
Exi |
01.02 |
— |
0 |
21 |
— |
c1 |
N50 |
— |
U |
2 |
— |
Т310 |
D |
— |
3 |
— |
L |
|
|
1 |
|
2 |
3 |
|
4 |
5 |
|
6 |
7 |
|
8 |
9 |
|
10 |
11 |
|
12 |
|
13 |
|
14 |
NN |
Parameter name |
Code |
Description |
||||||
1 |
Sensor type |
CTK, CTL, CTN, CTJ, CTM |
Mineral insulated cable thermocouple with type according to IEC 60584 and ASTM E230 |
||||||
2 |
Explosion protection |
Not filled |
general purpose electrical equipment |
||||||
Exi |
0ExiaIICT6 X, intrinsically safe circuit |
||||||||
Exd |
1ExdIICT6, explosion-proof enclosure |
||||||||
3 |
Modification |
01.01 |
Sensing element without mounting elements |
||||||
01.02 |
Mineral insulated cable thermocouple without mounting elements |
||||||||
4 |
Cable gland |
0 |
standard cable gland |
Not permitted for 1ExdIICT6 |
|||||
А |
for unarmoured cable in metal hose RZCH-15 |
||||||||
В |
for unarmoured cable in metal hose MRPI-15 |
||||||||
C |
for unarmoured cable in metal hose DN18 |
||||||||
D |
for unarmoured cable in metal hose DN20 |
||||||||
E |
for unarmoured cable in metal hose DN12 |
||||||||
F |
for pipe assembly, М20х1,5 internal thread |
||||||||
G |
for pipe assembly, output external thread G1/2 |
||||||||
H |
for unarmoured cable, 6.5 - 14 mm diameter |
||||||||
I |
for unarmoured cable, 3.2 - 8.7 mm diameter |
||||||||
J |
for cable with internal/external sheath diameter: 6,1-11,7/9,5-15,9, single-line wire armoured cable |
||||||||
К |
for cable with internal/external sheath diameter: 3,1-8,7/6,1-11,5, all armour types |
||||||||
L |
for cable with internal/external sheath diameter: 6,5-14/12,5-20,9, all armour types |
||||||||
5 |
Sensor terminal |
000 (only for 01.01) |
Free electrode ends |
IP00 |
general purpose |
||||
006 (only for 01.01) |
Free electrode ends with fitting |
IP00 |
general purpose |
||||||
002; 004) |
male connector |
IP00 |
general purpose |
||||||
005 |
terminal block |
IP00 |
general purpose |
||||||
10; 13 |
plastic head |
IP55 |
general purpose |
||||||
15; 16; 17; 18; 19 |
aluminium head |
IP66/IP68 |
1ExdIICT6 / 0ExiaIICT6 X |
||||||
20; 22; |
aluminium head |
IP65 |
general purpose |
||||||
14, 21; 23; 24; 25; 26; 28; 29 |
aluminium head |
IP66 |
0ExiaIICT6Х or general purpose |
||||||
27 |
stainless steel |
IP66 |
0ExiaIICT6Х or general purpose |
||||||
6 |
Sensor class |
c0; c1; c2 |
For further details see table 5 page 2-9 |
||||||
7 |
Output signal, transmitter accuracy symbol, see table 5, page 2-10 |
Not filled |
analogous signal (mV) according to NSC |
||||||
Т40 |
For terminal heads >14 |
4-20 mА |
for c0 |
||||||
Т50; Т70 |
for c1 |
||||||||
Т80; Т100 |
for c2 |
||||||||
H25 |
4-20 mА +HART |
Individual sensor calibration (c1) |
|||||||
H40 |
for c0 |
||||||||
H50 |
for c1 |
||||||||
H80 |
for c2 |
||||||||
8 |
Thermocouple hot junction design |
О |
exposed junction, |
general purpose |
|||||
G |
grounded junction, |
general purpose |
|||||||
U |
ungrounded junction, |
1ExdIICT6 / 0ExiaIICT6 X / general purpose |
|||||||
9 |
Number of wire couple |
Not filled |
1 wire couple |
||||||
2 |
2 wire couples (2 junctions) |
||||||||
10 |
Cable outer sheath material |
S10 |
Steel 12Cr18Ni10Т (only for CTL) |
||||||
S321, S316 |
AISI 321, AISI 316 |
||||||||
Т310 |
AISI 310 |
||||||||
Т446 |
AISI 446 |
||||||||
Т600 |
INCONEL 600 |
||||||||
Т740 |
ALLOY 740 |
||||||||
11 |
Cable sheath thickness |
Not filled |
standard sheath thickness (see table 1 introduction) |
||||||
D |
double sheath thickness (see table 1 introduction) |
||||||||
12 |
Outer diameter |
0.5; 1; |
size (mm) on Customer's choice |
general purpose |
|||||
1.5; 2; 3; 4; 4.5; 4.6; 5; 6 |
1ExdIICT6 / 0ExiaIICT6 X / general purpose |
||||||||
13 |
Probe length |
10÷100 000 |
probe length L to the working end, mm |
||||||
14 |
Additional data (for terminal head 006) |
М20/M18 |
thread М20х1,5 (electrode), М18х1 (working end) |
||||||
М20/M10 |
thread М20х1,5 (electrode), М10х1 (working end) |
CTK 01.02-005 - c2 – U2 – S321 – 4,5 – 500 |
Product type |
CT |
cable thermocouple |
Type of TC |
K |
chromel-alumel |
|
Explosion protection |
― |
general purpose |
|
Modification |
01.02 |
without mounting elements |
|
Cable gland |
0 |
no |
|
Wring (terminal head code) |
05 |
terminal block, IP00 |
|
Tolerance class |
c2 |
second class |
|
Output signal (accuracy class) |
― |
analogous |
|
Junction type, number of pairs |
U2 |
iwo, ungrounded |
|
Cable sheath material |
S321 |
Steel AISI 321 |
|
Cable diameter |
4.5 |
mm |
|
Probe length |
500 |
mm |
|
Extension neck length |
― |
|
|
CTK Exi 01.02-029 – c1 – U2 – Т310D – 4,5 – 2000 |
Product type |
CT |
cable thermocouple |
Type of TC |
K |
chromel-alumel |
|
Explosion protection |
Exi |
0ExiaIICT6 X |
|
Modification |
01.02 |
without mounting elements |
|
Cable gland |
0 |
standard |
|
Wring (terminal head code, connector) |
29 |
IP65 |
|
Tolerance class |
c1 |
first class |
|
Output signal (accuracy class) |
― |
analogous |
|
Junction type, number of pairs |
U2 |
iwo, ungrounded |
|
Cable sheath material |
Т310D |
AISI 310, double sheath thickness |
|
Cable diameter |
4.5 |
mm |
|
Insertion length |
2000 |
mm |