02.08

02.08 sensors are designed for short-time melt temperature measurement in electrolyte pot.
Cable temperature-sensing element with diameter 2 or 3 mm (cable sheath material - steel AISI 310) is located outside of protective tube. Extension length should be agreed with the Customer.
Immersion part length is not more than 250 mm.
Mounting sections can be manufactured according to the Customer's drawings.
New thermocouple design - CTx 02.15 modification - developed in cooperation with specialists of OAO RUSAL Sayanogorsk is recommended for electrolyte pots.
The benefit of 02.15 modification is short thermal reaction time and, subsequently, faster melt parameter measurement and longer thermocouple useful life.
In 02.15 modification cable temperature-sensing element with 1.5 mm diameter is located outside of protective tube. Extension length should be agreed with the Customer.
Immersion part length is not more than 120 mm.
Mounting sections can be manufactured according to the Customer's drawings.
02.15 thermocouple design is covered by utility model patents NN 66040, 133923.

Technical characteristics

Hot junction

one

 

Vibration resistance GOST R 52931

group V3

Seismic resistance MSK-64

grade 9 for unit installation up to 70 m above zero mark

Nominal (rated) pressure

0,1 MPa

Climatic category GOST 15150

UHL2Ambient temperature: -60..+120ºС for general purpose products

Calibration

Only initial during production, are not subject 
to periodic calibration

Response time τ 0,63:

02.08

 

02.15

 

Reliability measures

Not rated

Temperature range

CT type

Modification

Thermowell material

Group of operating conditions

Application
temperature, ºС

Calibration
interval

Mean lifetime

CTK, CTN

02.08

S10

IV

-200…+1100

Not rated

02.15

- 200…+1000

Execution options

CTK

 

02.15

0

60

c1

U

 

Т45

8

L

/

l

-

L1

/

L2

1

 

2

 

3

4

 

5

 

6

7

 

8

 

9

 

10

 

11

 

12

 

13

 

NN

Parameter name

Code

Description

1

Sensor type

CTK, CTN

Mineral insulated cable thermocouple with type according to IEC 60584 and ASTM E230

2

Modification

02.08

 

02.15

 

3

Terminal head

0

Free electrode ends 50mm

IP65

general purpose

2

miniature plug

IP40

general purpose

4

standard plug

IP40

general purpose

4

Wire version (see "Alternative designs" table, pages 1-14)

50

Stranded conductor, silicon / shield / silicon insulation - shield is insulated from sensor body and does not have a terminal

60

Stranded conductor, PTFE / shield / PTFE insulation - shield is insulated from sensor body and does not have a terminal

5

Sensor class designation

c1;  c2

For further details see table 5 page 2-9

6

Hot junction
design

G

grounded junction,

U

ungrounded junction

7

Number of wire couples

Not filled

1 wire couple

8

Outer sheath
material

S10

steel 12Cr18Ni10T

9

Outer diameter

4.5

For 02.15

13

For 02.03

10

Probe length, L

500÷2000

For 02.05 probe length can be up to 1250 mm

11

extension wire length

250÷10,000

specify size (mm):250, 320, 500, 1000, 2000, 3150 and more

12

Distance from sensor edge to mounting surface L2

60÷200

specify dimensions in mm

Only for 02.15

Distance from sensor edge to mounting element L2

L1÷250

Examples of product designation

CTK 02.08-050 - c1 - G - S10 - 13 - 1300/1250

Product type

CT

cable thermocouple

Type of TC

K

chromel-alumel

Explosion protection

-

general purpose

Modification

02.08

 

Terminal head

0

Free electrode ends

Wire type

60

silicon / shield / silicon

Tolerance class

c1

first class

Junction type

G

grounded

Working end material

S10

steel 12Cr18Ni10T

Sheath diameter

13

mm

Probe length

1300

mm

Wire length

1250

mm