02.29
02.29
These thermocouples are designed for solid body temperature measurement, for example, bearing blocks. Sensors can be of explosion protection type 0ExiaIICT6 X according to GOST 30852.10-2002. For further de-tails see "Alternative designs & Ordering information" below. If required, thermocouples with 4-20 mА DC signal and/or digital signal via HART, PROFIBUS-PA, FOUNDATION Fieldbus protocol, can be equipped with remote measuring transmitters
Hot junction |
one or two |
Ungrounded or Grounded |
Vibration resistance GOST R 52931 |
group F3 |
|
Nominal (rated) pressure |
0,1 MPa |
|
Seismic resistance MSK-64 |
grade 9 for unit installation up to 70 m above zero mark |
|
Climatic category GOST 15150 |
UHL2Ambient temperature: -60..+120ºС for general purpose products |
|
Calibration |
MI 3090-2007 - for sensor fitting length 20 to 250 mm |
Group of operating conditions |
Probability of |
Specified lifetime |
Mean |
Guarantee |
I |
0.95 for 40 000 hours |
5 years |
10 years |
5 years |
II |
0.95 for 16 000 hours |
2 years |
4 years |
2 years |
CT type |
Modification |
Group of operating conditions |
Application |
Calibration interval |
Mean lifetime |
CTK, CTN, CTL |
02.09 |
I |
- 40…+150 |
5 years |
10 years |
II |
- 40…+200 |
2 years |
4 years |
||
02.23 |
I |
- 40…+400 |
5 years |
10 years |
|
02.29 |
- 40…+600 |
Response time τ 0,63:
Hot junction |
Sensor response time depending on diameter, s |
|||
02.23, 02.29 |
02.09 |
|||
d = 3,0 |
d = 4,5 |
d = 5,0 |
d = 8,0 |
|
Insulated from sheath |
1.0 |
2.0 |
8.0 |
8.0 |
Uninsulated from sheath |
0.5 |
1.0 |
3.0 |
5.0 |
CTK |
|
Exi |
02.09 |
— |
0 |
60 |
— |
c1 |
— |
U |
|
— |
S10 |
— |
8 |
— |
L |
/ |
|
l |
- |
|
1 |
|
2 |
3 |
|
4 |
5 |
|
6 |
|
7 |
8 |
|
9 |
|
10 |
|
11 |
|
12 |
13 |
|
14 |
NN |
Parameter name |
Code |
Description |
||||
1 |
Sensor type |
CTK, CTN, CTL |
Mineral insulated cable thermocouple with type according to IEC 60584 and ASTM E230 |
||||
2 |
Explosion protection |
Not filled |
general purpose electrical equipment |
||||
Exi |
0ExiaIICT6 X, intrinsically safe circuit |
||||||
3 |
Modification |
02.09 |
based on thermocouple wire |
||||
02.23, 02.29 |
based on thermocouple cable |
||||||
4 |
Terminal head |
0 |
Free electrode ends 50mm |
IP65 |
0ExiaIICT6Х or general purpose |
||
5 |
Wire version (see "Alternative designs" table, pages 1-14) |
50 |
Stranded conductor, silicon / shield / silicon insulation |
||||
60 |
Stranded conductor, PTFE / shield / PTFE insulation |
||||||
63 |
stranded conductor, PTFE / PTFE / outer armour insulated from sensor body |
||||||
80 |
stranded conductor, PTFE insulation, in metal hose |
02.23 and 02.29 |
|||||
6 |
Sensor class designation |
c0; c1; c2 |
For further details see table 5 page 2-9 |
02.23, 02.29 |
|||
c1, c2 |
02.09 |
||||||
7 |
Hot junction |
G |
grounded junction, |
general purpose |
|||
U |
ungrounded junction |
0ExiaIICT6 or general purpose |
|||||
8 |
Number of wire couples |
Not filled |
1 wire couple |
||||
2 |
2 wire couples (2 junctions) |
||||||
9 |
Outer sheath |
S10 |
steel 12Cr18Ni10T |
02.09 |
|||
S321, S316 |
AISI 321, AISI 316 |
02.23, 02.29 |
|||||
10 |
Outer diameter, d |
5, 8 |
mm |
02.09 |
|||
3, 4.5, 6 |
mm |
02.23, 02.29 |
|||||
11 |
Probe length, L |
20 |
dimensions in mm |
d=5 mm |
02.09 |
||
30 |
d=8 mm |
||||||
10÷1000 |
d=3 mm, 4.5 mm |
02.23, 02.29 |
|||||
12 |
Number of extension leads |
Not filled |
One extension lead, number of wire couples is stated in item 8 |
U, U2 |
|||
2х |
Two leads, one wire couple each |
U2, except for 80 lead |
|||||
13 |
Wire length ℓ |
250÷10,000 |
specify size (mm):250, 320, 500, 1000, 2000, 3150 and more |
||||
14 |
Fitting standard size |
Not filled |
Fitting М8х1 |
d=5 mm |
02.09 |
||
Fitting М12х1.5 |
d=8 mm |
||||||
М8, М10, М12, М16, М20 |
Fitting М8х1, М10х1, М12х1.5, М16х1.5, М20x1.5 |
02.23, 02.29 |
CTK Exi 02.29-080 – c0 - U – S316 - 4.5 - 55/800/4000-М10
|
Product type |
CT |
cable thermocouple |
Type of TC |
K |
chromel-alumel |
|
Explosion protection |
Exi |
0ExiaIICT6 X |
|
Modification |
02.29 |
|
|
Terminal head |
0 |
Free electrode ends |
|
Wire type |
80 |
PTFE in metal hose |
|
Tolerance class |
c0 |
zero class |
|
Junction type |
U |
ungrounded |
|
Working end material |
S316 |
Steel AISI 316 |
|
Sheath diameter |
4.5 |
mm |
|
Probe length |
55 |
mm |
|
Cable part length |
800 |
mm |
|
Wire length |
4000 |
mm |
|
Threaded fitting |
М10х1 |
|