Technical characteristics

Connection diagram

2-wire

tolerance class В, С (see item 9 at page 6-5)

3-wire

tolerance class АА, А, В, С

4-wire

Vibration resistance GOST R 52931

group V3

Seismic resistance MSK-64

grade 9 for unit installation up to 70 m above zero mark

Climatic version
GOST 15150

UHL2Ambient temperature:

-60..+120ºС for general purpose products

-60..+85ºС for Ex version with analogous signal

Calibration

- GOST 8. 461-2009

Response time:

does not exceed 10 seconds

Reliability indicators

Group of operating
conditions

Probability of
failure-free operation

Specified lifetime

Mean
lifetime

Guarantee
conditions

I

0.95 for 40 000 hours

5 years

10 years

5 years

II

0.95 for 16 000 hours

2 years

4 years (6 years)*

2 years

* - Increased mean lifetime with 0,6 failure-free operation possibility for the given period.

Temperature range

TC type

Group of    
operating  
conditions

Tolerance
class

Application
temperature, °С

Cal. int.

Mean lifetime

CRTD

II

B, C

– 50…+150

2 years

4 years

PRTD

I

A, B, С

– 50…+150

5 years

10 years

Execution options

PRTD

 

 

204

0

60

Pt100

В

3

S10

8

L

/

l

 

1

 

2

3

 

4

5

 

6

 

7

8

 

9

 

10

 

11

 

12

 

 

NN

Name

Code

Description

1

Sensor type

CRTD

Copper resistance temperature detector

PRTD

Platinum resistance temperature detector

2

Explosion protection

Not filled

general purpose electrical equipment

Exi

0ExiaIICT6 X, intrinsically safe circuit

3

Modification

204

see draft

4

Terminal head

0

Free electrode ends 50mm

IP65

0ExiaIICT6Х or general purpose

2

miniature plug

IP40

general purpose

4

standard plug

IP40

general purpose

5

Sensor terminal
head (see "Alternative
designs"
page 1-15)

50

Stranded conductor, silicon / shield / silicon insulation - shield is insulated from sensor body and does not have a terminal

60

Stranded conductor, PTFE / shield / PTFE insulation - shield is insulated from sensor body and does not have a terminal

67

Stranded conductor, PTFE / shield / PTFE insulation - shield is insulated from sensor body and does not have a terminal

80

stranded conductor with PTFE
insulation in metal hose

6

Type of TC

50М, 100М, 50P, 100P, Pt100, Pt500

NSC according to GOST 6651-2009

7

Tolerance class

АА, А, В, С

Tolerance class according to GOST 6651-2009

8

Connection diagram

3, 4

3- and 4-wire connection diagram for class АА, А

2, 3, 4

2-, 3-, 4-wire connection diagram for class В, С

9

Sheath material

S10

steel 12Cr18Ni10T

10

Outer diameter, mm

3

for 67 modification wire

4

for 60 modification wire

5

for 50 modification wire

11

Probe length, L, mm

60÷100

 

12

Extension wire length

100÷30,000

specify dimensions in mm 500, 1000, 2000 3150 and more

Examples of product designation

PRTD 204-080-Pt100-В3-S10-3-150/3000

Product type

PRTD

Platinum resistance temperature detector

Explosion protection

general purpose

Modification

204

 

Terminal head

0

Free electrode ends

Wire code

80

metal hose, IP65

Type of TC

Pt100

 

tolerance class and connection diagram

В3

Class B, diagram 3-wire

Output signal (accuracy class)

analogous according to NSC

Sheath material

S10

steel 12Cr18Ni10T

Working end diameter

3

mm

Probe length L

150

mm

Wire length ℓ

3000

mm