300

These sensors are designed for temperature measurement of nonaggressive liquid and gaseous media, that do not destruct thermowell material. It is also possible to measure solid body temperature.  Sensors can be of explosion protection type 0ExiaIICT6 X. Further details see in "Alternative designs" below.
Movable fitting UNKJ 031 (see "UNKJ units and components" section) is recommended for sensor installation.

If required, thermocouples with  4-20 mА DC signal and/or digital signal via HART, PROFIBUS-PA, FOUNDATION Fieldbus protocol, can be equipped with remote measuring transmitters.

Technical characteristics

Connection diagram

2-wire

tolerance class В, С (see item 9 at page 6-5)

3-wire

tolerance class АА, А, В, С

4-wire

Vibration resistance GOST R 52931

group V3

Seismic resistance MSK-64

grade 9 for unit installation up to 70 m above zero mark

Climatic version
GOST 15150

UHL2Ambient temperature:

-60..+120ºС for general purpose products

-60..+85ºС for Ex version with analogous signal

Calibration

- GOST 8. 461-2009

Response time

Sensor response time depending on diameter, s

d = 4

d = 5

d = 6

8

12

16

Reliability indicators

Group of operating
conditions

Probability of
failure-free operation

Specified lifetime

Mean
lifetime

Guarantee
conditions

I

0.95 for 40 000 hours

5 years

10 years

5 years

II

0.95 for 16 000 hours

2 years

4 years (6 years)*

2 years

* - Increased mean lifetime with 0,6 failure-free operation possibility for the given period.

Temperature range

TC type

Group of    
operating  
conditions

Tolerance
class

Application
temperature, °С

Cal. int.

Mean lifetime

CRTD

II

А

– 50…+120

2 years

4 years

B, C

– 50…+150

PRTD

I

A, B, С

– 50…+150

5 years

10 years

II

АА

– 50…+150

2 years

4 years

Execution options

PRTD

 

Exi

300

0

60

Pt100

В

3

S10

8

L

/

l

 

 

1

 

2

3

 

4

5

 

6

 

7

8

 

9

 

10

 

11

 

12

 

13

 

NN

Name

Code

Description

1

Sensor type

CRTD

Copper resistance temperature detector

PRTD

Platinum resistance temperature detector

2

Explosion protection

Not filled

general purpose electrical equipment

Exi

0ExiaIICT6 X, intrinsically safe circuit

3

Modification

300

see draft

4

Terminal head

0

Free electrode ends 50mm

IP65

0ExiaIICT6Х or general purpose

2

miniature plug

IP40

general purpose

4

standard plug

IP40

general purpose

5

Sensor terminal
head (see "Alternative
designs"
page 1-15)

50

Stranded conductor, silicon / shield / silicon insulation - shield is insulated from sensor body and does not have a terminal

60

Stranded conductor, PTFE / shield / PTFE insulation - shield is insulated from sensor body and does not have a terminal

6

Type of TC

50М, 100М, 50P, 100P, Pt100, Pt500

NSC according to GOST 6651-2009

7

Tolerance class

АА, А, В, С

Tolerance class according to GOST 6651-2009

8

Connection diagram

3, 4

3- and 4-wire connection diagram for class АА, А

2, 3, 4

2-, 3-, 4-wire connection diagram for class В, С

9

Sheath material

S10

steel 12Cr18Ni10T

10

Outer diameter, mm

4

for 60 modification wire

5 or 6

for 50 modification wire

11

Probe length, L, mm

60÷160

 

12

Extension wire length

100÷30,000

specify dimensions in mm 500, 1000, 2000 3150 and more

13

Additional
parameter

Not filled

Should be filled if required

Examples of product designation

PRTD 300-060-Pt100-B3-S10-4-100/5000

Product type

PRTD

Platinum resistance temperature detector

Explosion protection

general purpose

Modification

300

 

Terminal head

0

Free electrode ends

Wire code

60

PTFE sheath, IP65

Type of TC

Pt100

 

tolerance class and connection diagram

В3

Class B, diagram 3-wire

Output signal (accuracy class)

 

analogous according to NSC

Sheath material

S10

steel 12Cr18Ni10T

Working end diameter

4

mm

Probe length L

100

mm

Wire length ℓ

5000

mm