Mounting electric heating cables EHC-M
Mounting electric heating cables EHC-M
These heating cables are designed for outer heating of nozzles and working surfaces of moulding machines, extruders, press dies, and various fittings and pipelines.
Heating element is made of
KNMSNH-N cable 2 or 3 mm diameter (Dc), H20Ni80 nichrome cable conductor, 12Cr18Ni10T steel sheath.
It is permitted to bend heating cable along the length (even to make a loop or coil) to put in required zone, if it is used in complex-geometry equipment or hard-to-get-at places. Cable can bear one bending around cylinder diameter, which equals to ten times cable diameter.
For AC or DC main connection electric heaters are equipped on default with current-carrying wires 250 mm long, made of PRKA wire in high-temperature insulation (up to 180°С). Lead length can be increased.
On customer's request electric heater can be equipped with M5 threaded contact bar. At the time of order this request should be specified as version 2
operating surface temperature of electric heater does not exceed 600°С – in running condition under heat removal with natural air convection.
EH modification |
Diameter, Dc, mm |
Length, Lc, mm |
Electric |
Running |
EHC-М |
2 |
11390 |
250 |
220 |
8900 |
320 |
|||
7120 |
400 |
|||
5600 |
500 |
|||
4500 |
630 |
|||
3600 |
800 |
|||
6000 |
1000 |
|||
4900 |
1250 |
|||
3 |
4350 |
1500 |
||
5950 |
2000 |
Limit allowable deviation of nominal power according to GOST 13268-88: –10% to +5%.
EHC - М Dc х Lc. N. U (version 2)
EHC-М 2х5600. 500. 220 – mounting electric heating cable, cable diameter 2 mm, mounting length 5600 mm, power 500 W, running voltage 220 V (wire leads 250 mm long).