03.06

Multipoint assemblies, modification 03.06 are designed for temperature measurement along axis of heat treatment furnace.
03.05 modification structure for multipoint measurement is an assembly of 02.01 modification thermocouples. Number of measurement points (from 3 to 10) equals to number of thermocouples in an assembly. Compensating wire length equals to 1000 mm or should be specified at the time of order. 03.06 modification multipoint assembly is designed for installation inside special thermowells of process equipment. Thermocouple edges should be pressed up to thermowell walls or spaced inside thermowell by spring properties of a ring formed near hot junction. The assembly is designed for 60 mm thermowell inner diameter (analogous to THK 2988), and is mounted on common header flange (flange without mounting holes).
Sensors can be of explosion protection type 0ExiaIICT6 X  according to GOST 30852.10-2002. For further details see "Alternative designs & Ordering information" below.

Technical characteristics

Hot junction

one or two

Ungrounded

Vibration resistance GOST R 52931

group V3

Seismic resistance MSK-64

grade 9 for unit installation up to 70 m above zero mark

Climatic category GOST 15150

UHL2 Ambient temperature:

-60..+120ºС for general purpose products

-60..+85 ºС for Ex version with analogous signal

Calibration

Not subject to periodic calibration Should be put out of operation after operating resource depletion

Reliability indicators

Group of operating conditions

Probability of
failure-free operation

Guarantee
conditions

I

0.95 for 40 000 hours

5 years

II

0.95 for 16 000 hours

2 years

III

0.95 for 8 000 hours

1 year

IV

Not rated

Not rated

Temperature range

CT type

Measurement
range, ºС

Group of operating conditions

Specified lifetime

Cable selection

Sheath diameter

Sheath material

CTK

– 40 .. + 600

I

5 years

3; 4,5;  6

S321; S316; T310; Т446; T600

– 200 ..+ 800

II

2 years

3; 4,5;  6

S321

– 200..+ 900

3; 4,5;  6

S316;  T310;  T600

– 200..+ 1000

III

1 year

3

T310;  Т446;  T600

– 200..+ 1100

4.5;  6

T310;  Т446;  T600

– 40..+ 1300

IV

Not rated

4.5;  6

T600

CTN

– 40 ..+ 800

I

5 years

3;  4.5

Т310; Т600; Т740

– 200 ..+ 1000

II

2 years

3

T310;  T600

– 200 ..+ 1100

4.5

T310;  T600

3;  4.5

Т740

– 200 ..+ 1100

III

1 year

3

Т740, Т600

– 200 ..+ 1200

4.5

Т740

– 40 ..+ 1300

IV

Not rated

4.5

Т740

CTL

– 40 ..+ 600

I

5 years

3; 4; 4.6; 5; 6

S10

– 100 . + 800

II

2 years

3; 4; 4.6; 5; 6

CTJ

– 40 ..+ 760

II

2 years

3;  4.5

S321, S316

Response time τ 0,63:

Hot junction

Sensor response time depending on diameter, s

d = 3.0

d = 4,0

d = 4,5;  4,6

d = 5,0

d = 6,0

Insulated from sheath

1.0

1.5

2.0

3.0

4.0

Uninsulated from sheath

0.5

1.0

1.0

1.5

2.0

Execution options

CTK

 

Exi

03.06

0

50

c1

5

U

 

S321

3

Ln

l

List of length

1

 

2

3

 

4

5

 

6

 

7

8

9

 

10

 

11

 

12

13

 

14

 

NN

Name

Code

Description

1

Sensor type

CTK

cable thermocouple chromel-alumel

CTL

cable thermocouple chromel-copel

CTN

cable thermocouple nichrosil-nisil

CTJ

cable thermocouple iron-konstantan

2

Explosion protection

Not filled

general purpose electrical equipment

Exi

0ExiaIICT6 X, intrinsically safe circuit

3

Modification

03.05, 03.06

 

4

Terminal head

0

Free electrode ends 50mm

5

Wire version (see "Alternative designs" table, pages 1-14)

50

Stranded conductor, silicon / shield / silicon insulation - shield is insulated from sensor body and does not have a terminal

60

Stranded conductor, PTFE / shield / PTFE insulation - shield is insulated from sensor body and does not have a terminal

6

Tolerance class

c0, c1;  c2

For further details see table 5 page 2-9

7

Number of points

1…20

Number of temperature monitoring points (levels)

8

Sensor hot junction design

G

grounded junction, general purpose

U

ungrounded junction

9

Number of wire couples

Not filled

1 wire couple

2

2 wire couples

10

Reinforcement material

S10

Steel 12Cr18Ni10Т (only for CTL)

S321

Steel AISI 321

S316

Steel AISI 316

Т310

Steel AISI 310

Т446

Steel AISI 446

Т600

INCONEL 600

Т740

ALLOY 740

11

Outer diameter

3;4; 4,5; 4,6; 5; 6

size (mm) on Customer's choice

12

Probe length Ln

10÷100 000

Length of the lowest (the most distant) element of the multipoint sensor

13

Length l

250÷20,000

Extension wire length

14

List of length

L1, L2,…,Ln

List of probe length values for all measuring points.

Examples of product designation

CTK Exi 03.06-050 - c1 - 5U2 - S316 - 3 – 12000/1000 – L1=1000, L2=3000, L3=5000, L4=7000, L5=12000 – Multipoint temperature sensor, design modification 03.06 based on cable thermocouples, modification version 050 with extension leads silicon/screen/silicon 1000 mm long, tolerance class 1, two ungrounded junctions (U2), cable sheath material - steel AISI 316 (S316), cable thermocouple diameter 3 mm, Measuring point length values L1=1000, L2=3000, L3=5000, L4=7000, L5=12000. Explosion protection - "Intrinsically safe circuit ia", 0ExiallCT6 X.