04.01
04.01
Sensors are designed for liquid and loose media temperature measurement by immersion (sensor 04.01), and also solid surface temperature measurement by contact method (sensors 04.03 – 04.06).
Cable temperature-sensing elements of the first tolerance class are used in surface temperature sensor modifications 04.01–04.06.
Cable temperature-sensing elements are armoured with steel tubes 4-8 mm diameter.
Sensor pressing to the surface is equal to 5-15 H.
sensor tolerance class: к1 for details see table 5 page 2-9
Individual corrections to temperature values should be obtained together with the secondary unit in compliance with MI 1607-87.
Note: surface temperature sensors can be supplied with HH506RA-type secondary units. Uncertainty of measurement of these units is equal to ±(0,3+0,05%Т), where Т – measurable temperature value. The unit has two measuring channels. The unit operates on "krona" battery. The unit supports the following thermocouple types: K, J, T, E, R, S, N. The unit allows to store up to 1000 measured values. The unit can be connected to PC. Description see in "Enclosures" section.
Hot junction one, grounded
TC type |
Operating temperature range, *С |
Cable sheath and reinforcement material |
CTK, |
0 to 500 |
S10 – steel 12Cr18Ni10Т |
Thermal response time *, t0,95, с: 20
* thermal response time (t0,95) – period of time required for thermocouple response to temperature step change by thermocouple signal change, which corresponds to 95% of specified step change.
Extension lead length should be selected within the range: 500, 1000, 1250, 1600, 2000 mm.
Thermocouple type |
Design |
Tolerance |
Hot |
Reinforcement |
Outer |
Insertion |
||
modification |
typical |
min |
max |
|||||
CTK, |
04.01 |
-060, -260, -050, -250 for CTK; -063 for CTL |
c2 |
G |
S10 |
8.0 |
320 |
1000 |
04.03 |
||||||||
04.04 |
||||||||
04.05 |
||||||||
04.06 |
6.0, 8.0 |
* – see Appendix for modification (extension lead) description. A thermocouple clip can be installed at the end of extension lead at customer's request (see section 11).
CTхх 04.ХХ-ХХХ - к2 - G - S10 - D - L / ,
where – extension lead length, D – reinforcement outer diameter.
CTK 04.05-062 - к2 - G - S10 - 8 - 500 / 1000 – chromel-alumel temperature sensor, modification 04.05-062 with extension lead in PTFE sheath, tolerance class 2, grounded junction (G), cable temperature-sensing element in steel armour (S10), reinforcement outer diameter 8 mm, probe length 500 mm, extension lead length 1000 mm. Contact surface based on heat-insulating tile.